초록 |
Objectives: The purpose of this study was to evaluate the relevance of adjusting a urinary sample for urine hippuric correction value and its effects. Urinary biological monitoring data are typically adjusted to a constant creatinine and specific gravity concentration to correct for variable dilutions among spot samples. This study was conducted to evaluate the suitability of adjusting the urinary concentrations of urine creatinine and specific gravity(SG). Methods: We measured the concentrations of hippuric acid, in spot urine samples collected from control(119), case(120) individuals. The value of hippuric acid was adjusted by SG and urinary creatinine(HPLC Jaffe). Results: The major results were as follows. The concentrations of urinary creatinine and SG for the control group were 1.84 g/L(SD 0.99) for arithmetic mean and 1.56 g/L(GSD 1.86) for geometric mean by HPLC method, 1.57 g/L (SD, 0.82) for arithmetic mean and 1.33 g/L(GSD 1.85) for geometric mean by Jaffe method, 1.028(SD 0.09) for arithmetic mean and 1.02(GSD 1.06) for geometric mean by refractometer. Hippuric acid levels were 0.40 g/L(SD 0.51) by arithmetic mean and 0.20 g/L(GSD 3.59). In that case the exposed group was 1.40 g/L(SD 0.58) for arithmetic mean and 1.28 g/L(GSD 1.55) for geometric mean by HPLC method, 1.27 g/L(SD 0.56) for arithmetic mean and 1.14 g/L(GSD 1.62) for geometric mean by Jaffe method, 1.045 L(SD 0.27) for arithmetic mean and 1.02(GSD 1.13) for geometric mean by refractometer(P 0.05). After adjustment, urine hippuric acid was correlated with creatinine(HPLC Jaffe)(r=0.723, P |