초록 |
The ventilation systems composed three types of side vent (roll-up) 'SV', side vent+roof vent 'SV+RV', and side vent+roof fan 'SV+RF' with 7.5 m spacing, with specific set point temperatures for ventilation: SV ( $35^{ circ}C$ open / $33^{ circ}C$ close), SV+RV or SV+RH ( $35^{ circ}C$ open/ $33^{ circ}C$ close for root ventilation and $37^{ circ}C$ open / $35^{ circ}C$ close for side vent). In the treatment of SV+RV, although the average daily maximum temperature inside the greenhouse temporarily increased by $38-40^{ circ}C$ , thermal stress by high temperature did not occur and the disease incidence (%) of powdery mildew and downy mildew on the oriental melon were 25 - 75% lower than in the conventional SV treatment. In the SV treatment, the disease incidence (%) of powdery mildew and downy mildew were 1.4 - 7.7% and 4.2 - 15.9% for 'Deabakkul', and 20.3 - 22.8% and 2.8 - 11.3%, for 'Ildeungkkul'. The yield for one month was higher in the treatment of SV+RV than those in other treatments, with values of 2,105 kg/10a for 'Deabakkul' and 2,537 kg/10a for 'Ildeungkkul'. The simultaneous treatment with side vent and roof vent resulted in 16.2% higher yield (18.1% higher marketable yield) than that in the SV treatment for 'Deabakkul'. |