The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

논문 개요

기관명, 저널명, ISSN, ISBN 으로 구성된 논문 개요 표입니다.
기관명 NDSL
저널명 Imaging science in dentistry
ISSN 2233-7822,2233-7830
ISBN

논문저자 및 소속기관 정보

저자, 소속기관, 출판인, 간행물 번호, 발행연도, 초록, 원문UR, 첨부파일 순으로 구성된 논문저자 및 소속기관 정보표입니다
저자(한글) Kajan, Zahra Dalili,Davalloo, Reza Tayefeh,Tavangar, Mayam,Valizade, Fatemeh
저자(영문)
소속기관
소속기관(영문)
출판인
간행물 번호
발행연도 2015-01-01
초록 Purpose: Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Materials and Methods: Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying 'Sharpening 2' and 'Noise Reduction' processing options to the original images; (2) applying the 'Magnification 1:3' option to the image obtained in the first step; (3) enhancing the original images by using the 'Diagonal/'option; (4) reviewing the changes brought about by the third step of image processing and then, applying 'Magnification 1:3'; (5) applying 'Sharpening UM' to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying 'Magnification 1:3.' Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. Results: The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). Conclusion: This study shows that the application of 'Sharpening UM' along with the 'Magnification 1:3' processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.
원문URL http://click.ndsl.kr/servlet/OpenAPIDetailView?keyValue=03553784&target=NART&cn=JAKO201520165686987
첨부파일

추가정보

과학기술표준분류, ICT 기술분류,DDC 분류,주제어 (키워드) 순으로 구성된 추가정보표입니다
과학기술표준분류
ICT 기술분류
DDC 분류
주제어 (키워드) Dental Caries,Dental Digital Radiography,Image Enhancement