기업조회

본문 바로가기 주메뉴 바로가기

논문 기본정보

페노피브레이트 유연물질 표준품 대체시험법 개발

논문 개요

기관명, 저널명, ISSN, ISBN 으로 구성된 논문 개요 표입니다.
기관명 NDSL
저널명 약학회지
ISSN 0377-9556,
ISBN

논문저자 및 소속기관 정보

저자, 소속기관, 출판인, 간행물 번호, 발행연도, 초록, 원문UR, 첨부파일 순으로 구성된 논문저자 및 소속기관 정보표입니다
저자(한글) 김정현,김민영,권은경,이광문,최돈웅
저자(영문)
소속기관
소속기관(영문)
출판인
간행물 번호
발행연도 2015-01-01
초록 Analytical method for related substances can be categorized into two methods depending on the necessity of reference standard (RS). The analytical method of related substances with RS is fast and accurate, but it's very expensive and technically difficult to synthesize RS due to their complicated structure. Another method is using relative retention time (RRT) and relative response factor (RRF) which are already validated with RS. Validation of this method is not easy and time consuming, but once it has been developed, it can save cost and time. In this study, we developed the analytical method for related substances of fenofibrate using RRT and RRF. We validated the method by evaluating specificity, linearity, accuracy and precision according to the 'Manual for Guideline Application for Validation of Analytical Procedures' of MFDS. Also, we calculated RRT and RRF between fenofibrate and fenofibrate related substances. The results of this study showed high specificity for fenofibrate and fenofibrate related substances. Correlation coefficient(r) of all substances were more than 0.99, and the recovery of fenofibrate, fenofibrate related substance I, II and III were 99.44%, 100.84%, 99.14% and 101.58%, respectively. Precision of fenofibrate and its related substances were ranged between RSD 0.29% and 0.93%. Quantification limits of fenofibrate, fenofibrate related substance I, II and III were determined to be $0.03{ mu}g/ml$ , $0.05{ mu}g/ml$ , $0.04{ mu}g/ml$ and $0.02{ mu}g/ml$ , respectively by confirming signal to noise ratio of each chromatogram. The RRT for fenofibrate related substance I, II and III were determined to be 0.35, 0.41 and 1.34, respectively. Also, the RRF for fenofibrate related substance I, II and III were determined to be 1.28, 0.98 and 0.79, respectively. The developed method was applied to determine contents for fenofibrate related substances in commercial fenofibrate (active pharmaceutical ingredient). As a result, developed analytical methods of related substances will be used for revising the monograph of fenofibrate in Korean Pharmacopoeia revision and contribute quality control of drugs by improving cost and time consuming problem of RS.
원문URL http://click.ndsl.kr/servlet/OpenAPIDetailView?keyValue=03553784&target=NART&cn=JAKO201521866699594
첨부파일

추가정보

과학기술표준분류, ICT 기술분류,DDC 분류,주제어 (키워드) 순으로 구성된 추가정보표입니다
과학기술표준분류
ICT 기술분류
DDC 분류
주제어 (키워드) Korean Pharmacopoeia,fenofibrate,related substances,impurity test,reference standard