기업조회

본문 바로가기 주메뉴 바로가기

장비 및 시설 기본정보

위상잡음및 알란편차 측정기

장비 개요

기관명, 장비번호, 제작사, 모델명, 장비사양, 취득일자, 취득금액 순으로 구성된 표입니다.
기관명 ZEUS
장비번호
제작사 Symmetricom
모델명 5120A
장비사양
취득일자 2012-06-11
취득금액

보유기관 및 이용정보

보유기관명, 보유기관코드, 활용범위, 활용상태, 표준코드, 표준분류명, 시설장비 설명, 장비이미지코드, 장비위치주소, NFEC 등록번호, 예약방법, 카타로그 URL, 메뉴얼 URL, 원문 URL, 첨부파일 순으로 구성된 표입니다.
보유기관명 한국표준과학연구원
보유기관코드
활용범위
활용상태
표준코드 D100
표준분류명
시설장비 설명 Simultaneous Phase-Noise and
Allan-Deviation Measurements
1 - 400 MHz Input Frequency Range
Measurement Results Displayed
within Seconds
No External Data Processing Required
Industry Leading Accuracy
Makes Measurements with
Input and Reference at Different
Frequencies
Allan-Deviation Measurements
to over 300 Days
Phase-Noise Measurements as Close
as 0.1 mHz from the Carrier
No Measurement Calibration
Required: saves time
Displays Internal Noise Estimate
Easy to Use Graphical User Interface
Excellent Phase-Noise
Measurements Down to -170 dBc/Hz
(typical) 10 kHz from the carrier
(10 MHz input)
QUICK ACCURATE COST EFFECTIVE
MEASUREMENTS NOW POSSIBLE
OVER 400 MHz INPUT FREQUENCY
RANGE
Symmetricoms new 5125A makes accurate
phase-noise measurements on signals
from 1 MHz to 400 MHz covering the full
range of the most commonly used frequency
references. The 5125A which requires
absolutely no configuration displays
measurement results seconds after the
Start button is pressed.
Symmetricom the worlds leading provider
of high performance frequency standards
has designed the third generation
all-digital 5125A to meet the most
demanding requirements. The 5125A s
industry-leading close-in phase-noise
performance -140 dBc/Hz at a 1 Hz offset
(10 MHz fundamental) makes it the perfect
solution to characterize the lowest noise
frequency references available such as
those used in RADAR and satellite
communications.
The all-digital architecture employed in
the 5125A uses advanced high-speed
low-noise analog-to-digital converters in a
patented architecture that does not require
a phase-lock loop to make measurements.
This provides multiple benefits for 5125A
users. First the input carrier signals can be
characterized much more accurately than
before to within 0.1 mHz of the carrier.
Second the measurements can be used to
simultaneously evaluate the short-term
stability. Last but not least the user does
not need to calibrate each individual
measurement setup.
In addition to phase-noise measurements
the 5125A simultaneously performs a
variety of other measurements which
enables users to more fully characterize
their Devices Under Test
The industry-standard stability metric for
short-term stability the Allan deviation
(ADEV) can be measured out to more than
300 days; the frequency and phase vs. time
are plotted in real time; and the frequency
counter displays 13 digits of precision in
1 second.
ESTABLISHED HERITAGE IN
TIME AND FREQUENCY
MEASUREMENTS
Over 25 years of research at the National
Institute of Standards and Technology (NIST)
and in private industry have come to fruition
in Symmetricoms phase noise test sets
which employ both direct sampling of the RF
waveforms as well as cross correlation
making it possible to easily characterize the
highest performance time and frequency
references. The 5125A builds on the experience
gained with the Symmetricoms ground
breaking 5120A by extending the direct sampling
approach throughout the frequency
range up to 400 MHz.
QUICKEST START-TO-FINISH
MEASUREMENTS
Thanks to the 5125As innovative internal
architecture it requires no user configuration
or calibration and thus makes phasenoise
measurements in a matter of seconds.
5125A
High-Performance Extended-Range Phase Noise and Allan Deviation Test Set
5125A High-Performance Extended-Range Phase Noise
and Allan Deviation Test Set
TIMING TEST & MEASUREMENT
장비이미지코드 http://nfec.ntis.go.kr/storage/images/equip/photo/201206/.thumb/20120611193115.JPG
장비위치주소 대전 유성구 도룡동 452 한국표준과학연구원 응용물리동 106-1
NFEC 등록번호 NFEC-2012-06-164214
예약방법
카타로그 URL
메뉴얼 URL
원문 URL http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0033193
첨부파일

추가정보

과학기술표준분류, ICT 기술분류, 주제어 순으로 구성된 표입니다.
과학기술표준분류
ICT 기술분류
주제어 (키워드)