발광측정기

장비 개요

기관명, 장비번호, 제작사, 모델명, 장비사양, 취득일자, 취득금액 순으로 구성된 표입니다.
기관명 ZEUS
장비번호
제작사 Biotek
모델명 Synergy H1 Hybrid Reader
장비사양
취득일자 2012-08-23
취득금액

보유기관 및 이용정보

보유기관명, 보유기관코드, 활용범위, 활용상태, 표준코드, 표준분류명, 시설장비 설명, 장비이미지코드, 장비위치주소, NFEC 등록번호, 예약방법, 카타로그 URL, 메뉴얼 URL, 원문 URL, 첨부파일 순으로 구성된 표입니다.
보유기관명 광주과학기술원
보유기관코드
활용범위
활용상태
표준코드 B212
표준분류명
시설장비 설명 The Synergy H1 Hybrid Reader is BioTek's high-performance multi-mode plate reader designed for the life science research and drug discovery markets. Its fluorescence detection system uses deep blocking filters and dichroic mirrors for the best level of performance in research and screening applications. The dedicated absorbance detection system is monochromator-based providing the best level of flexibility in this read mode. And by utilizing dedicated optical elements for each individual detection technique Synergy 2 offers uncompromised performance and the lowest limits of detection.
Detection modes include Fluorescence Intensity Luminescence and UV-visible Absorbance. Its three broad-spectrum light sources have been chosen for optimal illumination and excitation in all applications.
Measurement Techniques: Fluorescense Intensity Glow and Flash Luminescence UV-Vis Absorbance FRET TR-FRET BRET Area Scanning Spectral Scanning
Unique Optical System: a narrow band monochromator optimized filter/dichroic mirror pairing and three broad spectrum light sources achieve superior performance in all read modes
Compatible with Take3 Micro-Volume Plate: sixteen 2 μL microspots for low volume DNA/RNA 260 nm measurements. Saves precious samples very fast and simple process.
High Sensitivity: dedicated optical elements optimized for each specific modality result in the lowest limits of detection available in one compact instrument
Modular Design: purchase only what you need and easily upgrade later as experimental requirements expand
High Throughput: optimized for screening assays including 1536-well read modeGeneral
Detection mode Fluorescence Luminescence UV-Visible Absorbance
Read method End point kinetic spectral scanning well-area scanning
Microplate types 6- to 1536-well plates (luminescence 1-384)
PCR plates
Compatible with Take3 Multi-Volume Plate with 2 μL microspots
Temperature control 4°C above ambient to 65°C; +0.5°C at 37°C
Shaking Yes
Software Gen5™ included
Control through USB or serial port
Automation Yes
Light source Tungsten Halogen Lamp
Sensitivity 100 amol of biotinylated-LCK-P peptide 25 μL/well in 384-well plate
Dynamic range >6 decades
Reading speed 2 minutes typical for 96-well plate
Detection system Ultra Low Noise PMT
Absorbance
Light source SQ Xenon Flash
Wavelength selection Monochromator
Wavelength range 200 - 999 nm 1 nm increment
Bandpass 2.4 nm
Dynamic range 0 - 4.0 OD
Resolution 0.0001 OD
Pathlength correction Yes
Monochromator wavelength accuracy +2 nm
Monochromator wavelength repeatability +0.2 nm
OD accuracy <1% at 2 OD typical
<3% at 3.0 OD typical
OD linearity <1% from 0 to 3.0 OD typical
OD repeatability 6 decades
Bandpass Filter dependent
Detection system PMT
Reading speed 96: 11 seconds
384: 22 seconds
1536: 42 seconds
Luminescence
Sensitivity 10 amol ATP typical (flash)
Wavelength range 300 - 700 nm
Dynamic range >6 decades
Detection system Low noise PMT
Fluorescence Polarization
Light source Tungsten Halogen
High Energy DPR Xenon Flash (optional)
Sensitivity 3 mP at 1 nM fluorescein typical
Wavelength selection Deep blocking filters/mirrors
Wavelength range 400 - 700 nm (320 - 850 nm option)
Time-Resolved Fluorescence
Light source High Energy DPR Xenon Flash
Sensitivity Europium 60 fM typical (12 amol/well 96-well plate; 6 amol/well 384-well plate)
Wavelength selection Deep blocking filters/mirrors
Wavelength range 200 - 700 nm (850 nm option)
Reagent Dispensers
Number 2 syringe pumps
Dispense volume 5 - 1000 μL in 1 μL increment
Dead volume 1.1 mL 100 μL with backflush
Physical Characteristics
Power 250 Watts max
Dimensions 17"W x 17.5"D x 14.5"H (43.5 x 44.5 x 37.3 cm)
Weight 60 lbs (27 kg)
Regulatory
Regulatory CE and TUV marked. In Vitro Diagnostic use models are available.Wide Range of Applications: with built-in temperature control shaking and optional dual reagent injector virtually any microplate-based application is possible
Scre
장비이미지코드 http://nfec.ntis.go.kr/storage/images/equip/photo/201304/.thumb/2013042695058189.jpg
장비위치주소 광주 북구 오룡동 광주과학기술원 지스트대학 지스트대학 B동 4층 412호
NFEC 등록번호 NFEC-2013-04-178257
예약방법
카타로그 URL
메뉴얼 URL
원문 URL http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0039211
첨부파일