고분해능 X선형광분석기
| 기관명 | ZEUS |
|---|---|
| 장비번호 | |
| 제작사 | Panalytical |
| 모델명 | Axios mAX |
| 장비사양 | |
| 취득일자 | 2012-02-09 |
| 취득금액 |
| 보유기관명 | 대구경북과학기술원 |
|---|---|
| 보유기관코드 | |
| 활용범위 | |
| 활용상태 | |
| 표준코드 | B522 |
| 표준분류명 | |
| 시설장비 설명 | 1. X-ray Generator (1) Max. Power : 4kW (2) Max. kV : 60kV (3) Max. mA : 150mA (4) Control Step : IkV / 1mA (5) Stability : 0.005% / 10% mains variation (6) kV / mA switching method : Isowatt switching (7) Switching Time : 2.5 sec (8) X-ray tube type : End-Window type Rh target (9) X-ray tube window thickness : ≤50㎛ 2. Spectrometer (1) Irradiation type : Sample surface down (2) Analysis element range : 4Be to 92U (3) Atmosphere : Vacuum / Air / He (4) Primary Beam Filter : 4 positions or more (5) Primary Collimator Mask : Max. 6 ( 37 30 27 2010 6 mm ) (6) Analyzing Crystal : 6 positions Bi-direction -V ~ U range : LiF220 -K ~ U range : PX-10 -P ~ Cl range : GE111 -Al ~ Cl range : PE002 -O ~ Mg range : PX1 -B : PX4 (7) Collimator : 3 positions (8) Powder sample protection and reduction of cross contamination & wear system must be included in the machine. 3. Goniometer (1) Type : /2 decoupled with Direct Optical Position Sensing(DOPS) (2) Angular reproducibility : 0.0001 deg and 2 (3) Scanning speed : 10° /s (600° 2 /mm ) (4) Slewing speed : 40° /s (2400° 2 /min) (5) Cabinet Temp. Stabilization : ±0.05°C (6) Angular Accuracy :0.0025° (7) Movement must be controlled by DC motor. 4. Detector : 3 detectors must be put in same movement. (1) Analysis range -Flow counter : 4Be ~ 30Zn -Scintillation counter : 22Ti ~ 92U -Duplex sealed Xe counter : 21Sc ~ 28Ni (2) Max. count rate -Flow counter : 3000 kcps -Scintillation counter : 1500 kcps -Duplex counter : 4500 kcps (3) Analyzer type must be DMCA with digital signal processor (4) Pulse shift correction: Automatic Dynamic (5) Dead time correction: Automatic (6) Hi-per channel for C analysis 5. Auto Sample Changer : Robotic arm X-Y Loading (1) Max sample loading position: 168 position 6. He flushing system for liquid sample analysis (1) Max. flow : 0.5 1/min 7. Sample Tray and Holder (1) Sample Tray : Pre-defined sample loading positions (2) Sample Holder dia. 32 mm |
| 장비이미지코드 | http://nfec.ntis.go.kr/storage/images/equip/photo/201211/.thumb/20121115175900.jpg |
| 장비위치주소 | 대구 달성군 현풍면 상리 50-1 대구경북과학기술원 중앙기기센터 3층 303 |
| NFEC 등록번호 | NFEC-2013-02-175205 |
| 예약방법 | |
| 카타로그 URL | |
| 메뉴얼 URL | |
| 원문 URL | http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0035850 |
| 첨부파일 |
| 과학기술표준분류 | |
|---|---|
| ICT 기술분류 | |
| 주제어 (키워드) |