액체섬광계수기
기관명 | ZEUS |
---|---|
장비번호 | |
제작사 | Perkin Elmer |
모델명 | Tri-Carb2910TR |
장비사양 | |
취득일자 | 2012-10-08 |
취득금액 |
보유기관명 | 안전성평가연구소 |
---|---|
보유기관코드 | |
활용범위 | |
활용상태 | |
표준코드 | A504 |
표준분류명 | |
시설장비 설명 | 1. Automatic optimum counting performance for user application 2. External data processing system (Windows XP based analysis software) 3. Self-correction and verification for any electronic change assuring optimum performance assessment accuracy and precision for monitoring-background efficiencies and chi-square values using normalization factors. 4. Storing of quench curves in seventy-five isotope libraries which automatically determine the unquenched window settings to DPM of dual-labeled H-3 and C-14 samples 5. Gives sample independent quench correction and provides single CPM DPM dual DPM results corrected for color and chemical quenching chemiluminescence volume. 6. Automatic half life correction 7. Sample quality positive sample identification 8. Multi-parameter linear MCA with an effective resolution of 0.1keV offers an extended dynamic quench range and provides multi-parameter spectrum analysis to correct for luminescence color quenching and background radiation.1. Liquid Scintillation Counter 1 set 1. Liquid Scintillation Analyzer 1) Operation software for the Windows XP operating system 2) Hypertext on-line comprehensive HELP 3) External PC system 4) Robust downloading sample changer mechanism 5) TR-LSC (Time-Resolved Liquid Scintillation Counting) 6) Multi-parameter linear MCA(Multichannel Analyzer) with an effective resolution of 1/10 keV offers an extended dynamic quench range and provides multi-parameter spectrum analysis to correct for luminescence color quenching and background radiation. 7) Spectrum base counting and data management system 8) A cassette-loaded bi-directional sample conveyor mechanism - 408 samples (20ml Vial) or 720 samples (4 or 7ml) 9) Positive sample identification provides protocol number cassette number sample number and user selectable printout and data file storage of the counting time and date for each sample. 10) Quick-Count sample loading for 30 independent protocols (with unlimited assays) 11) Automatic Quality Assurance 12) Spectral Index of Sample quench indicating parameter 13) 133Ba low energy external standard source and tSIE(transformed Spectral Index of External standard) calculations 14) Automatic Efficiency Control 15) Quench standard spectra 16) Luminescence detection and reporting 17) Enhanced Direct DPM (Disintegration Per Minute) 18) Single and dual label DPM Counting 19) Live spectraview automatic spectrum display 20) Automatic spectrum polt (on demand) per sample allows spectral documentation of samples. 21) Password protection prevents unwanted changes to saved assays. 22) Printed header contains instrument serial number user ID and drive and path of stored data. 23) Assay-specific user selectable coincidence resolving time 24) On-screen editing 25) Electrostatic controller automatically helps neutralize static electricity on a all types of vials. 26) Automatic processing of count data to final results 27) Spectral unfolding separates and displays in color the individual radionuclide spectra of dual label samples. 28) 3-D (three-dimensional) spectral mapping 29) Half-life correction to any date and time 30) Activity Reporting is provided in Becquerels microCuries or picoCuries. 31) Custom output formatting to printer RS-232 and disk storage 32) User-definable calculations are available for custom data reporting. 33) Background subtraction can be nominated via sample entered value or stored IPA background spectrum. 34) Programmable single photon counting enables luminescence assay counting with optimized signal-to background ratio. It overcomes problems associated with excessive luminescence. 35) Preset time (up to 9999.99 minutes) and preset error coincidence termination optimizes counting accuracy in the three counting regions. 36) Percent of standard calculations for single dual and triple label samples is present. 37) User adjustable assay-specific sample precount delay permits dark adaptation of samples before counting. 38) Group |
장비이미지코드 | http://nfec.ntis.go.kr/storage/images/equip/photo/201211/.thumb/20121126153224.jpg |
장비위치주소 | 경남 진주시 문산읍 삼곡리 854번지 안전성평가연구소 경남환경독성본부 2층 235 |
NFEC 등록번호 | NFEC-2013-02-175564 |
예약방법 | |
카타로그 URL | |
메뉴얼 URL | |
원문 URL | http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0035960 |
첨부파일 |
과학기술표준분류 | |
---|---|
ICT 기술분류 | |
주제어 (키워드) |