오실로스코프
기관명 | ZEUS |
---|---|
장비번호 | |
제작사 | Yokogawa |
모델명 | DL1740E |
장비사양 | |
취득일자 | 2006-06-26 |
취득금액 |
보유기관명 | 단국대학교 천안캠퍼스 |
---|---|
보유기관코드 | |
활용범위 | |
활용상태 | |
표준코드 | D105 |
표준분류명 | |
시설장비 설명 | · Input channels : 4 (701730 701740) 2 (701715) · Input coupling : AC 1 MΩ DC 1 MΩ DC 50 Ω GND · Input impedance : 1 MΩ±1.0% 50 Ω±1.0% · Voltage axis sensitivity setting Range· Input channels : 4 (701730 701740) 2 (701715) · Input coupling : AC 1 MΩ DC 1 MΩ DC 50 Ω GND · Input impedance : 1 MΩ±1.0% 50 Ω±1.0% · Voltage axis sensitivity setting Range - For 1 MΩ input : 2 mV/div to 10 V/div (steps of 1 2 or 5) - For 50 Ω input : 2 mV/div to 1 V/div (steps of 1 2 or 5) · Maximum input voltage - For 1 MΩ input (frequency of 1 kHz or less) : 400 V (DC + ACpeak)(282 Vrms CAT II) - For 50 Ω input : 5 Vrms or 10 Vpeak (and neither are exceeded) · Frequency characteristics - For 1 MΩ input (using passive probe model 700988; specified at probe tip) : 10 V/div to 10 mV/div : DC to 400 MHz 5 mV/div to 2 mV/div : DC to 300 MHz - For 50 Ω input : 1 V/div to 10 mV/div : DC to 500 MHz 5 mV/div to 2 mV/div : DC to 400 MHz · A/D conversion resolution : 8 bits (24 LSB/div) · Maximum sampling rate - Real-time sampling mode - Interleave mode ON : 1 GS/s - Interleave mode OFF : 500 MS/s - Repetitive sampling mode : 100 GS/s · Maximum record length - Interleave mode ON : 2 MW/CH - Interleave mode OFF : 1 MW/CH · DC accuracy : ±(1.5% of 8 div + offset voltage accuracy) · Offset voltage axis accuracy - 2 mV/div to 50 mV/div : ±(1% of setting + 0.2 mV) - 100 mV/div to 500 mV/div : ±(1% of setting +2 mV) - 1 V/div to 10 V/div : ±(1% of setting + 20 mV) · Time axis setting range - 1 ns/div to 50 s/div (for record length of 10 kW or greater) - 1 ns/div to 5 s/div (for record length of 1 kW) · Time base accuracy : ±0.005% · External clock input - Input frequency range : 40 Hz to 20 MHz (continuous clock signal only) · Measuring Periodically Fluctuating Amplitudes · Pulse Count · Envelope and Roll modes for simultaneously observing both slow and fast signals · Simple and Enhanced Triggers for Reliable Capturing of a Variety of WaveformsMeasuring Periodically Fluctuating Amplitudes Pulse Count Envelope and Roll modes for simultaneously observing both slow and fast signals Simple and Enhanced Triggers for Reliable Capturing of a Variety of Waveforms |
장비이미지코드 | http://nfec.ntis.go.kr/storage/images/equip/photo/201102/.thumb/20110218121554.jpg |
장비위치주소 | 충청남도 천안시 동남구 단대로 119 (안서동) 단국대학교 천안캠퍼스 제3과학관 5층 530 |
NFEC 등록번호 | NFEC-2011-02-143687 |
예약방법 | |
카타로그 URL | |
메뉴얼 URL | |
원문 URL | http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0028158 |
첨부파일 |
과학기술표준분류 | |
---|---|
ICT 기술분류 | |
주제어 (키워드) |