장비 개요

기관명, 장비번호, 제작사, 모델명, 장비사양, 취득일자, 취득금액 순으로 구성된 표입니다.
기관명 ZEUS
장비번호
제작사 Metrohm
모델명 850 Professional IC
장비사양
취득일자 2010-05-28
취득금액

보유기관 및 이용정보

보유기관명, 보유기관코드, 활용범위, 활용상태, 표준코드, 표준분류명, 시설장비 설명, 장비이미지코드, 장비위치주소, NFEC 등록번호, 예약방법, 카타로그 URL, 메뉴얼 URL, 원문 URL, 첨부파일 순으로 구성된 표입니다.
보유기관명 제주테크노파크
보유기관코드
활용범위
활용상태
표준코드 B404
표준분류명
시설장비 설명 1. Quantitative and qualitative analysis of wide range inorganic compounds 2. Chemically inert. PEEK or polymer flowpath of such as pump tube column packing material injector loop surppression device Detector cell & etc. are compatible with all aqueous eluent of pH 0-14.
3. Meets US EPA Method 300.0 300.1 300.0300.6 300.7 302.0 309.0 314.0 218.6 200.10 7199.0 9056 ASTM Method D2036 D4327-91 D4856-88 D5085-90 D5257 AWWA429 ISO 14911:1998(E) NIOSH Method S173200835095022600460056011 6701 7604 7903 and OSHA Method ID-104ID-108 ID-177ID-180ID-182ID-188 ID-190ID-202 with Micromembrane Suppressor or Self-Regenerating Suppressor(SRS).
4. Suppressors work by reducing the conductivity of the eluent while enhancing the conductivity of the analytes. This improves sensitivity stability and dynamic range for anions and cations.
5. Automated eluent generation minimizes time labor operation costs and eluent preparation errors.
6. This system is the premier Reagent-Free IC system. Reagent-Free IC eliminates variability and potential contamination providing a stable baseline higher sensitivity improved resolution and excellent reproducibility.
7. Superior Automatic data system offers extremely powerful data processing & control features audit trail intuitive database management.
8. The unique "system wellness" program which logs and reminds the chromatographer when calibration validation and routine maintenance is due on each module.Anions cations and ancat dual systems
Anion systems with or without suppression
Chemical suppression followed by CO2 suppression (sequential suppression)
Sequential suppression with inline ultrafiltration or dialysis (Prep1)
Sequential suppression with inline pre-concentration
Inline matrix elimination or inline calibration (Prep 2)
Sequential suppression with inline neutralization and inline cation removal (Prep 3)
Low pressure or high pressure gradientThey all come with your choice conductivity UV-VIS or electrochemical detectors. Anion configurations are available with low medium or high capacity suppressors. With the new generation you have the choice of a peristaltic pump or a dosino for suppressor regeneration. The new generation ICs also feature STREAM Suppressor Treatment with Reused Eluent After Measuring. This will eliminate the need to add DI water for suppressor rinsing.
장비이미지코드 http://nfec.ntis.go.kr/storage/images/equip/photo/201102/.thumb/20110210163002.JPG
장비위치주소 제주 서귀포시 남원읍 신례리 2162-43 제주테크노파크 생물종다양성연구소 3층 305
NFEC 등록번호 NFEC-2011-02-140866
예약방법
카타로그 URL
메뉴얼 URL
원문 URL http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0026114
첨부파일

추가정보

과학기술표준분류, ICT 기술분류, 주제어 순으로 구성된 표입니다.
과학기술표준분류
ICT 기술분류
주제어 (키워드)