전기수술기 분석장치
| 기관명 | ZEUS |
|---|---|
| 장비번호 | |
| 제작사 | FLUKE |
| 모델명 | QA-ES |
| 장비사양 | |
| 취득일자 | 2010-06-29 |
| 취득금액 |
| 보유기관명 | 을지대학교 성남캠퍼스 |
|---|---|
| 보유기관코드 | |
| 활용범위 | |
| 활용상태 | |
| 표준코드 | D101 |
| 표준분류명 | |
| 시설장비 설명 | 특징 의료기기에서 발생되는 Voltage나 Current 등을 출력량을 측정하여 Electrosurgical Unit(ESU)의 변형되는 상태를 확인 정상동작 여부의 진단구성및성능 -Continuous Operation: Continuous measurement of power current peak-to-peakvoltage (closed load only) and crest factor -Single Operation: Single measurement after the set delay time of the ESU output of powercurrent peak-to-peak voltage(closed load only) and crest factor -Power Distribution: Automatic measurement of power current peak- to-peak voltage (closed load only) and crest factor through a user-selectable load range -RF Leakage current: Provides connections and load configurations to measure HF leakage from both grounded and isolated equipment -RECQM : Test the“return electrode control qualitymonitoring” using the ESA internal loads활용분야 Electrosurgical Unit 의 정상동작 여부의 진단 |
| 장비이미지코드 | http://nfec.ntis.go.kr/storage/images/equip/photo/201012/.thumb/20101223145633.JPG |
| 장비위치주소 | 경기 성남시 수정구 양지동 을지대학교 212번지 을지대학교 성남캠퍼스 을지관 3층 303 |
| NFEC 등록번호 | NFEC-2010-12-130342 |
| 예약방법 | |
| 카타로그 URL | |
| 메뉴얼 URL | |
| 원문 URL | http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0018230 |
| 첨부파일 |
| 과학기술표준분류 | |
|---|---|
| ICT 기술분류 | |
| 주제어 (키워드) |