동결건조기

장비 개요

기관명, 장비번호, 제작사, 모델명, 장비사양, 취득일자, 취득금액 순으로 구성된 표입니다.
기관명 ZEUS
장비번호
제작사 Labconco
모델명 79340-10
장비사양
취득일자 2007-03-14
취득금액

보유기관 및 이용정보

보유기관명, 보유기관코드, 활용범위, 활용상태, 표준코드, 표준분류명, 시설장비 설명, 장비이미지코드, 장비위치주소, NFEC 등록번호, 예약방법, 카타로그 URL, 메뉴얼 URL, 원문 URL, 첨부파일 순으로 구성된 표입니다.
보유기관명 경기과학기술진흥원
보유기관코드
활용범위
활용상태
표준코드 C603
표준분류명
시설장비 설명 1. Upright stainless steel collector coil and chamber with stainless steel baffle capable of removing 2 liters of water in 24 hours and holding 6 liters of ice before defrosting. 2. Two 1/3 hp CFC-free and HCFC-free refrigeration systems used in series to cool collector to -84° C (-119° F). 3. Clear acrylic chamber lid 3/4" thick with neoprene gasket. 4. Brushed stainless steel and glacier white epoxy-coated steel exterior with blue accents. 5. LCD that displays system operating parameters set-up parameters and alarm messages. It may be user-configured to display vacuum in mBar Pa or Torr and temperature in ° F or ° C. It also displays total number of hours of refrigeration operation and since the refrigeration was serviced and the total number of hours of vacuum pump operation and since the vacuum pump was serviced (in hours). 6. Red alarm light that flashes and beeper that sounds to indicate that an abnormal system event has occurred including: power failure improper line voltage supply collector temperature rise above -40° C service vacuum pump (after 1000 hours of vacuum use) and moisture in collector. Pressing the Menu Switch displays the alarm message on the LCD. 7. LED vacuum and temperature “waves” for at-a-glance display of relative system vacuum and collector temperature. 8. Moisture sensor that prevents refrigeration or vacuum start-up when moisture is detected in the collector chamber area. 9. Vacuum control valve that maintains setpoint vacuum level.10. Vacuum break valve that bleeds air into the system when power to the freeze dryer or vacuum pump is shut off. If a power outage less than approximately 5 minutes occurs the freeze dryer will restart and the refrigeration and vacuum system will resume operation once power is restored. If the power failure is more than approximately 5 minutes and the collector warms above safe limits the freeze dryer will not automatically restart.11. Rear-mounted RS-232 port to t
장비이미지코드 http://nfec.ntis.go.kr/storage/images/equip/photo/201109/.thumb/20110909162058.JPG
장비위치주소 경기 수원시 영통구 이의동 864-1번지 광교테크노밸리 경기바이오센터 1층 시료전처리실
NFEC 등록번호 NFEC-2010-12-117739
예약방법
카타로그 URL
메뉴얼 URL
원문 URL http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0018978
첨부파일

추가정보

과학기술표준분류, ICT 기술분류, 주제어 순으로 구성된 표입니다.
과학기술표준분류
ICT 기술분류
주제어 (키워드)