하이브리드 큐토프 텐덤 질량분석기
기관명 | ZEUS |
---|---|
장비번호 | |
제작사 | Agilent Technologies |
모델명 | Accyrate MAss Q-TOF LC/MS system |
장비사양 | |
취득일자 | 2013-02-04 |
취득금액 |
보유기관명 | 연세대학교 |
---|---|
보유기관코드 | |
활용범위 | |
활용상태 | |
표준코드 | B602 |
표준분류명 | |
시설장비 설명 | 하이브리드 큐토프 텐덤 질량분석기는 정확한 분자량 측정 및 고분해능 스팩트럼 생산 능력을 이용하여 미지물질에 대한 구조를 신뢰성 높게 동정 할 수 있어 정성적 분석에 주로 활용됨.1) General Specification. (1) Mass Resolution : Measured at m/z 1522 after automatic tuning greater than 20000 (2) Dynamic range : 5 decades or better (3) Mass accuracy of MS mode (Electrospray on-column 400 ul/min) - Measured at the (M+H)+ ion of reserpine (m/z 609.2807) using an internal mass reference - Better than 2 ppm RMS as measured from 10 repeat injections(typically 1 to 2 ppm). (4) Sensitivity of MS mode (Electrospray on-column 400 uL/min) - 1 pg LC/MS injection of reserpine. Signal-to-noise for the reserpine (M+H)+ at m/z 609.2807 will give 10:1 RMS (typical 30:1 RMS) (5) Sensitivity of MS/MS mode (Electrospray on-column 400 μL/min) - 1 pg LC/MS injection of reserpine. Signal-to-noise for most intense product ions (174 195397448 m/z) will give 50:1 RMS (typical 200:1 RMS) (6) Spectral Acquisition rate of MS mode - m/z 100 to 1700 in MS mode while maintaining a resolution of 20000 at m/z 2722 will be 20 spectra/sec. (7) Spectral Acquisition rate of MS/MS mode - m/z 100 to 1700 in MS/MS mode while maintaining a resolution of 20000 at m/z 1522 will be 1 MS and 10 MS/MS spectra/sec. (8) Scan mode - Include MS scan MS SIM MS/MS product Ion scan MRM MS/MS neutral loss/gain scan and parent ion scan. - Scan modes are time programmable for both polarity (positive & negative ion) and type of scan. (9) Autotune - Software control of MS tuning parameters for all Scan SIM MRM and linked Scan modes including neutral loss/gain. - All tune files can be stored as part of a method. - Positive and negative Autotune modes; Autotune can be customized. Calibrant delivery system is built into cabinet and under complete software control. No need for external syringe pump for MS tuning. Instrument can be tuned manually if desired. (10) Ion source - Flow rate compatibility : up to 2500 ul/min - Sunknown mixture에서 아주 적은 분자량 차이도 구분하여 정확한 분자식과 구조에 대한 정보를 제공하고 측정시간이 빠르고 측정 영역이 높은 편이므로 metabolomics/proteomics연구에 주로 활용됨. |
장비이미지코드 | http://nfec.ntis.go.kr/storage/images/equip/photo/201302/.thumb/2013021814220659.jpg |
장비위치주소 | 인천 연수구 송도동 송도과학로 85 - 진리관D 4층 431호 |
NFEC 등록번호 | NFEC-2013-02-175915 |
예약방법 | |
카타로그 URL | |
메뉴얼 URL | |
원문 URL | http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0037368 |
첨부파일 |
과학기술표준분류 | |
---|---|
ICT 기술분류 | |
주제어 (키워드) |