유전자 증폭기
기관명 | ZEUS |
---|---|
장비번호 | |
제작사 | Roche |
모델명 | Light Cycler 480 |
장비사양 | |
취득일자 | 2009-06-08 |
취득금액 |
보유기관명 | 농림축산검역본부 |
---|---|
보유기관코드 | |
활용범위 | |
활용상태 | |
표준코드 | B201 |
표준분류명 | |
시설장비 설명 | 1. Available in a high-throughput micro well plate-based cycler for 384 and 96 well format. 2. Rapid heating and cooling required to complete a 40-cycle 384-well qPCR run less than 60 minutes. 3. The unique and novel block eliminates the "edge-effect" found in so many block-based thermal cycler and is able to reach that setting temperature without needing too much equilibration time. 4. Advanced high-performance optical system for accurate data capture across the entire plate without fluorescence signal normalization. 5. Emission filters are able to work with the assay format of your choice including Fluorescence Resonance Energy Transfer (FRET) intercalating dyes (SYBR) Hydrolysis probes (Taqman) or hybridization probes. 6. For integrated workflow monitoring automated loading and automated sample-preparation this instrument is possible in combination with laboratory information management systems robotic equipment. 7. Supports automatic analysis and interpretation of Multi-way RT quantification and melting curve data. 8. It is a modular online PCR device for qualitative or quantitative detection of nucleic acids genotyping and mutation analysis. 9. More than 6 targets can be quantified on one PCR tube simultaneously.1. Multi-way RT PCR Instrument 1-1. Sample Format and Capacity - Changeable sample microwell plate 96well format and 384well plate format 1-2. Reaction Volumes - 5ul-20ul (384-well) 10ul-100ul (96-well) 1-3. Method of heating and cooling : Peltier based 1-4. Temperature range: 37℃~95℃or more broad 1-5. Heating/cooling rate : - Heating rate average of >3℃/s - Cooling rate average of >2.5℃/s 1-6. Maximum ramp rates : - Heating rate of >5℃/s - Cooling rate of >3.5℃/s 1-7. Heating lid : PCR without any overlay 1-8. Light Source : High-intensity broad-spectrum Xenon Lamp or comparative lamp 1-9. Detector : Cooled CCD camera 1-10. Multiplexing capable : 6 color or more 1-11. Average Run Time (40 Cycles) : <60 minutes. (96 well plate) 1-12. Dynamic range : 9 log of linear dynamic range or more 1-13. Sensitivity : 0.08 nM fluorescein detectable in all wells across the plate or more 1-14. Number of Reaction per day : Over 1152 sample wells per day 1-15. Chemistry format support : - DNA-binding dyes (SYBR Green I) - Hybridization probe (Hybprobe) - Hydrolysis Probe (Taqman probe) - Simple probe Molecular beacons and others ○ 사용활용 예시 3-1. Desktop : Pentium4 PC Operating System is Window XP 3-2. Display : 22" wide LCD TN panel 2ms 3-3. Printer : color laser 264 MHz 8-12 ppm 600 × 600 dpi 32M RAMor more over |
장비이미지코드 | http://nfec.ntis.go.kr/storage/images/equip/photo/201108/.thumb/20110831112500.jpg |
장비위치주소 | 경기 안양시 만안구 안양6동 농림수산검역검사본부 본부 농림축산검역본부 세균질병연구동 2층 공동실험실 |
NFEC 등록번호 | NFEC-2011-08-148270 |
예약방법 | |
카타로그 URL | |
메뉴얼 URL | |
원문 URL | http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0029813 |
첨부파일 |
과학기술표준분류 | |
---|---|
ICT 기술분류 | |
주제어 (키워드) |