초고속 액체 크로마토 그래피
기관명 | ZEUS |
---|---|
장비번호 | |
제작사 | Waters |
모델명 | ACQUITY UPLC I-Class |
장비사양 | |
취득일자 | 2014-09-02 |
취득금액 |
보유기관명 | 한국표준과학연구원 |
---|---|
보유기관코드 | |
활용범위 | |
활용상태 | |
표준코드 | B402 |
표준분류명 | |
시설장비 설명 | 1. New high-pressure fluidics module takes advantage of the unique small particle technology at optimized flow rates. The use of extremely small efficient particles with a wider range of linear velocities creates various results that surpass current HPLC technology. 2. New sample-handling design makes it possible to be performed with exceptionally low carry-over and reduced cycle time. When this system is interfaced with the new Sample Organizer it increases sample capacity by ten-fold unattended or without an additional system operator. 3. New high-speed data sampling detectors both optical and mass detectors contribute to increased sensitivity and help the management of the enhanced speed and resolution by Ultra Performance LC. Ultra low system volume is designed to optimize high efficiency separations.1.Ultra Performance LCSystem -Total System Bandsprad5σ:6to 9μL -Total System Delay Volume :<100μLorbetter -Composition Accuracy:±0.5% absolute (fullscale) from 5 to 90% from 0.5 to 2.0mL/min -Sample Manager Precision: <1% RSD 0.2 to 1.9 uL < 0.5% RSD 2.0 to 10.0uL 2.Photodiode Array Detector -Baseline Noise:+/-0.7x 10 - 5 AUorless 230 nm mediumshuntcell -Cell Volume : 500nL (analytical cell) or more. 3.Chromatography manager software -New Win 7 ProBased Active User Interface 4. System Suitability Option Software 5. Data Processing System 6. 12x32 Vial & SrwCap & pre-sltsepta(100pk) 7. Data Processing System1. New high-pressure fluidics module takes advantage of the unique small particle technology at optimized flow rates. The use of extremely small efficient particles with a wider range of linear velocities creates various results that surpass current HPLC technology. 2. New sample-handling design makes it possible to be performed with exceptionally low carry-over and reduced cycle time. When this system is interfaced with the new Sample Organizer it increases sample capacity by ten-fold unattended or without an additional system operator. |
장비이미지코드 | http://nfec.ntis.go.kr/storage/images/equip/photo/201409/.thumb/2014091192649385.jpg |
장비위치주소 | 대전광역시 유성구 가정로 267 (도룡동) 한국표준과학연구원 인증표준물질(CRM)동 1층 1160 |
NFEC 등록번호 | NFEC-2014-09-191353 |
예약방법 | |
카타로그 URL | |
메뉴얼 URL | |
원문 URL | http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0045160 |
첨부파일 |
과학기술표준분류 | |
---|---|
ICT 기술분류 | |
주제어 (키워드) |