장비 및 시설 기본정보

비표면적측정장치

장비 개요

기관명, 장비번호, 제작사, 모델명, 장비사양, 취득일자, 취득금액 순으로 구성된 표입니다.
기관명 ZEUS
장비번호
제작사 Bel Japan
모델명 BELSORP-mini II
장비사양
취득일자 2012-04-09
취득금액

보유기관 및 이용정보

보유기관명, 보유기관코드, 활용범위, 활용상태, 표준코드, 표준분류명, 시설장비 설명, 장비이미지코드, 장비위치주소, NFEC 등록번호, 예약방법, 카타로그 URL, 메뉴얼 URL, 원문 URL, 첨부파일 순으로 구성된 표입니다.
보유기관명 연세대학교
보유기관코드
활용범위
활용상태
표준코드 B704
표준분류명
시설장비 설명 Up to 3 samples can be measured independently and simultaneously.
Pore sizes of 0.35 to 200 nm in diameter can be measured.
Specific surface areas as low as 0.01 m2/g can be measured.
Up to 4 BELSORP-miniII units can be controlled from one computer.
Liquid nitrogen level control is no longer necessary by applying advanced free space measurement method (AFSM) invented by BEL which obtains high precision and high reproducible data.
Very compact space-saving unit
ISO 9277 and JIS Z 8830 compliant
BEL Japan has developed a unique method to compensate for dead volume in the sample tube. Conventional instruments require that the level of liquid nitrogen is kept constant during a sample measurement. This creates problems with temperature variations in the top of the tube large consumption of liquid nitrogen or requires a complicated liquid nitrogen system.
The BELSORP-mini does not require a constant liquid nitrogen level. The change in dead volume due to changes in liquid nitrogen level and temperature and atmospheric temperature are measured in another sample tube. For high precision measurements this is performed at the same time as a measurement but for high throughput applications this can be measured prior to the sample measurement. This method compensates for dead volume changes throughout the whole apparatus and so allows high accuracy data to be collected without time consuming or wasteful liquid nitrogen management.
The analysis software for BELSORP-mini is Windows based. Analysis data can be saved in CSV format to be opened in other spreadsheet software packages. The software is very user friendly making it possible to produce good quality analysis printouts for reports or notebooksMeasurement principle: Volumetric gas adsorption method +AFSM
Adsorptive: N2 Ar CO2 H2 and other non-corrosive gases
Analysis port: High accuracy mode ? 3 ports
Standard mode ? 2 ports
Specific surface area: 0.01m2/g and above (N2/77K depends on sample density)
Pore size distribution: 0.35 ? 200 nm in pore diameter
Pressure transducer: 133 kPa (1000Torr) ? 0.5 % of F.S. X 5 units
Dewar vessel: Volume: 2L
Holding time: 30H
Sample cell: Approx. 1.8cm3 (Option: 5 cm3)
Physical: W313 x H650 x D390mm 42kg
Power: Single phase: AC100 - 120V or 200--240V / 600VA
(450VA is for vacuum pump)
장비이미지코드 http://nfec.ntis.go.kr/storage/images/equip/photo/201208/.thumb/20120822110605.JPG
장비위치주소 서울 서대문구 신촌동 연세대학교 0 0 GS 산학협력관 3층 313
NFEC 등록번호 NFEC-2012-08-169005
예약방법
카타로그 URL
메뉴얼 URL
원문 URL http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0034543
첨부파일

추가정보

과학기술표준분류, ICT 기술분류, 주제어 순으로 구성된 표입니다.
과학기술표준분류
ICT 기술분류
주제어 (키워드)