섬유소재성분분석기
기관명 | ZEUS |
---|---|
장비번호 | |
제작사 | Thermo Electron |
모델명 | Nicolet 6700/8700 |
장비사양 | |
취득일자 | 2010-01-22 |
취득금액 |
보유기관명 | 한국의류시험연구원 |
---|---|
보유기관코드 | |
활용범위 | |
활용상태 | |
표준코드 | B502 |
표준분류명 | |
시설장비 설명 | 1. This system is a powerful tool for analyzing the sample of industrial materials, polymers, organics, ceramics, organometallic samples. 2. This instrument combines a continuous-scan Michelson Interferometer with a frictionless electromagnetic drive system. 3. The interferometer must employ a Digital Dynamic Alignment system which is controlled by DSP(Digital Signal Processing) for long-term stability & superior data accuracy. 4. The optic design must employ a Auto-Tune(Alignment) system for optimization of system throughput. 5. This system should have E.S.P.(Enhanced Synchronization Protocol) Technology for monitoring the performance of all key components to ensure data quality. 6. This system should have the capability of recognizing the accessory automatically, loading the correct operating parameters for unique experiment, and performing a set of quality checks to verify that the accessory and system are working optimally based on E.S.P.(Enhanced Synchronization Protocol) 7. This instrument should be Pinned-in place design includes the source, laser, mirrors, detector and other critical components for long-term stability and easy replacement 8. This instrument consists of the short pathlength optical layout from source to detector; a single mirror from the beamsplitter to the sample compartment & a single mirror from the sample compartment to the detector 9. This system can be interfaced/enhanced with NIR, FIR, IR Microscope, TGA, and Emission etc. 10. The IR source should be available with the dual mode to improve the lifetime and also fully controlled by the software . Turbo mode: 1250'C . Normal mode: 1150’C . Rest mode: 900‘C 11. This system has the capability for the rapid scan(Up to 40 spectra/second at 16 cm-1 ) to study of chemical kinetics, liquid phase1) Interferometer : Electromagnetic drive 90 degree Michelson type 2) Source : Electronically Temperature Controlled SiC Source (9,600-20cm-1) User selectable 3 temperature mode (Turbo, Stabilized, Rest Modes) controlled thru software. 3) Detector : DLaTGS w/KBr Detector (12,500-350cm-1) 4) Beamsplitter : KBr Beamsplitter (7,800 ~ 375cm-1) 5) Spectral range : 7,800 ~ 375cm-1 or wider Expandable 27,000~20cm-1 or wider 6) Resolution : 0.4cm-1 or better 7) Interferometer Alignment : Digital Dynamic Alignment 8) Ordinate Linearity : Less than ±0.07% T (ASTM Linearity) or better 9) Rapid Scan : better than 95 scans/sec 10) Linear Scan Velocities : user selectable 0.158 ~ 6.33cm/sec or better 11) Signal to Noise Ratio : <8.68 x 10-6 Abs. (peak-to-peak) or better <1.95 x 10-6 Abs. (RMS) or better 12) A/D converter : 24 bit high speed or better 13) External beam port : 5 beam ports or more 14) Automatic Accessory recognition & parameter set-up : Enhanced Synchronization protocol or equivalent 15) Interface : USB 2.0 16) All gold coated optics 17) Power : 220V, 5o/60Hz, 5A섬유소재에 관한 정보 분석 및 물성 평가 나일론, 폴리에스터, 아세테이트 면, 견, 아마 섬유 등 합성섬유 및 천연섬유의 물성 평가 가능 기타고분자 제품의 물성 평가 진행 가능 평가 등 |
장비이미지코드 | http://nfec.ntis.go.kr/storage/images/equip/photo/201310/.thumb/201310089562148.bmp |
장비위치주소 | 부산 해운대구 우동 부산시해운대구 우동 1470번지 에이스하이테크21 6층 610호 한국의류시험연구원 에이스하이테크21 6층 610호 6층 |
NFEC 등록번호 | NFEC-2013-10-183343 |
예약방법 | |
카타로그 URL | |
메뉴얼 URL | |
원문 URL | http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0046770 |
첨부파일 |
과학기술표준분류 | |
---|---|
ICT 기술분류 | |
주제어 (키워드) |