연구용 실체 현미경
기관명 | ZEUS |
---|---|
장비번호 | |
제작사 | Olympus |
모델명 | MVX10 |
장비사양 | |
취득일자 | 2012-06-28 |
취득금액 |
보유기관명 | 단국대학교 천안캠퍼스 |
---|---|
보유기관코드 | |
활용범위 | |
활용상태 | |
표준코드 | A201 |
표준분류명 | |
시설장비 설명 | 1) Zoom ratio : 1:10 (0.63x-6.3x) 2) Field number (F.N.) : 22 3) Tilting angle : 0°-23°continuously variable system 4) Fluorescence system - Type of light source : Metal Halide(2000-hour long-life time) - Filter change : 4 position turret - Filter : MGFPHQ/XL : BP 460-480 DM 485 BA 495-540 MRFPHQ/XL : BP 535-555HQ DM 565HQ BA 570-625HQ 5) Magnification : 1x 2x selection 6) Objectives : MVPLAPO 1X : NA 0.25 WD 65mm MVPLAPO 2XC : NA 0.5 WD 20mm 7) Stand : Large stand 8) Focusing unit : fine focusing unit ofr heavy loading 9) High Sensitivity Digital Camera : - Effective no. of pixels : 1344(H) x 1024(V)1. High fluorescence efficiency plus stereo observation. 2. Seamless observation from 4x to 125x. 3. Zoom factor up to 31 times. 4. Long WD for observation at optimum magnification. 5. Maximum specimen protection due to short exposure time. 6. complete system solutions for optimized recordings. 7. High sensitivity in VIS-NIR region 8. Hermetic vacuum sealed head 9. High resolution of 1.37 million pixels 10. Exposure time up to 4200sec 11. Low dark noise with peltier cooling for a dynamic range of 3000:1 12. Progressive scan interline CCD chip 13. Compatible with IEEE 1394-based digital camera specification Full remote control from PC via IEEE 1394b 14. Economical benchtop anesthesia system 15. Dedicated system for non-rebreathing circuits 16. Can be upgraded to a rebreathing system with the addition of a freestanding CO2 absorber system.17. Vaporizer settings are from 0.25%-5% in 1/4 increments up to 3% then 1/2 increments up to 5%. 18. Vaporizer Included Two Windows Level Display 19. Absorbs anesthetic vapors from the work area protecting personnel from exposure. 20. A self-contained portable unit requiring no extra ducting or ventilation. 21. Anesthesia Mask were designed to work directly with the animal adaptor. The nose bar is elevated and the mask is slid onto the tooth bar assembly. 22. Anesthesia Masks were designed with smaller animals in mind. They have a simple cylindrical shape with a rubber diaphragm. 23. Cost-effective solution for basic imaging applications such as digital photography multi-wavelength fluorescence image processing and image analysis. 24. Simple easy-to-use system for acquiring and processing images performing graphics functions and archiving and retrieving images. |
장비이미지코드 | http://nfec.ntis.go.kr/storage/images/equip/photo/201210/.thumb/20121012134406.jpg |
장비위치주소 | 충청남도 천안시 동남구 단대로 119 (안서동) 단국대학교 천안캠퍼스 약학대학 4층 413 |
NFEC 등록번호 | NFEC-2012-10-171319 |
예약방법 | |
카타로그 URL | |
메뉴얼 URL | |
원문 URL | http://www.zeus.go.kr/equip/read?equipId=Z-NTIS-0037655 |
첨부파일 |
과학기술표준분류 | |
---|---|
ICT 기술분류 | |
주제어 (키워드) |